Component Testing Procedures
!
WARNING
To avoid risk of electrical shock, personal injury or death; disconnect power to range before servicing, unless
testing requires power.
14 16026839
© 2006 Maytag Services
"Quick Test" Mode for Non-Self Clean Control
Follow procedure below to use the quick test mode. Entries must be made within 32 seconds of each other or the
control will exit the quick test mode.
1.
Press and hold
Cancel
and
Broil
keypads for 3 to 5 seconds within 5 minutes of applying power.
2. Once the control has entered the "Quick Test" mode, release both keypads.
3. Press each of the following keypads indicated in the table below.
NOTE:
Press the keypad once to activate the response.
Press the keypad a second time to deactivate the response.
Display will indicate the following:
Keypad Operation
[Bake]
Bake
relay activated
[Broil]
Broil
relay activated
[Timer]
DLB
relay activated
[Clock]
Alternate between
ODD
LED
SEGMENTS
and
EVEN LED
SEGMENTS
on each
key press
[Up Arrow]
EEPROM
version
number
[Down Arrow]
Code
version number
[Cancel]
Exit Factory Test Mode
Description of Error Codes
Error diagnostic codes can only be viewed by entering the Diagnostic Code Display Mode.
Each error code consists of four digits and each digit is described in the following table.
Digit Description
1
st
Primary System:
1 – Local to the control circuit board
3 – Sensor and/or meat probe
4 – Control input
2
nd
Measurable:
d – Diagnostic: measurable parameter
c – Control related, replace control
3
rd
Secondary
System:
Sequential
numbering
4
th
Oven Cavity:
1 – Oven
c – Control specific