Changing The Inner Light
Before removing the inner light, turn off the appliance first and then unplug the unit from the wall outlet.
Failure to do so could result in electrical shock or personal injury.
Remove two screws that fix the control box. While holding the control box, disconnect the LED
connector to the main PCB.
Remove the LED array by removing two screws.
Replace a new LED array and connect it to the main PCB.
Fix the LED array and
reinstall the control box.
Important:
The replacement of LED lamp can only be performed by an authorized technician.
Automatic Defrost
There is no need for manual defrosting of this appliance due to automatic defrosting function.
The ice build-up on the inner back wall during compressor operation will be automatically
defrosted once the compressor cycle is off.
Defrost water will drain out passing through the drain outlet in the inner back wall into a drain pan
located above the compressor, from where it evaporates.
CHANGING THE REVERSIBLE DOOR
This appliance is built with a reversible door. You have the choice of either opening it from the left or
the right side. In order to reverse the opening direction of your door, please follow these simple
instructions.
NOTE: If desired, please change the door swing prior to appliance installation.
Caution: To avoid personal injury to yourself and/or property, we highly recommend that
someone assist you during the door reversal process.
1) Remove the top hinge assembly and keep them
for later use.
2)
Disassemble the lower hinge plank by removing
2 hex flange locking bolts. Screw out the hinge
3) Remove the plug buttons from the upper left
holes and transfer them to the uncovered
holes on the right side. Be sure to press the
plug buttons firmly into the hole.
4) Re-install the top hinge assembly previously
removed in step 1 on the opposite side.
5) Re-install the lower hinge plank (with the hinge
pin on the opposite hole) previously removed in
6) Re-install the door assembly with the door
handle on the opposite side. (Rotating the
door assembly 180°).
7) Ensure that the door assembly is properly
aligned with cabinet before tightening the
screws.
pin from the hinge plank and re-screw it into the
other hole on the plank and keep it for later use.
step 2 onto the opposite side.