INSTALLATION INSTRUCTIONS
TRANSPORTATION AND STORAGE
During transportation, the cooking equipment should be carefully handled. DO NOT place it upside down. The
equipment should be stored in a well ventilated warehouse away from corrosive gas. If it needs to be stored
outside temporarily, make sure it does not come in contact with rain.
INSTALLATION NOTE
Before installing, verify that the type of gas (natural or propane) matches the specifications on the data plate,
which is located on the back or side of the appliance. Make sure the device is configured for the proper elevation.
Record your model and serial numbers for future reference in the space provided below. This information can be
found on the data plate.
Model No: _____________________________________ Serial No: ____________________________________
1.
Installation should be performed by certified technicians.
2.
Before installation, remove the outer plastic film if present and wipe off any residue on stainless steel with
a cloth and warm water. Be sure to rinse with clean water and a towel.
3.
Connection of the device should conform to provisions of gas safety, installation and usage.
4.
Installation from the outlet end of the gas flow meter or service regulator to the gas pipe of the device
should be performed by trained professional technicians. They should also test the cooking equipment first
and make any adjustments.
5.
The gas pressure should be set according to the type and pressure listed on the rating label. If the gas supply
pressure is 10% higher or lower than the rated pressure, please install a pressure regulator to adjust the gas
pressure. DO NOT use a medium or high pressure regulator.
6.
Check the gas type and pressure to make sure that they conform to those marked on the rating label. If
incorrect gas type or pressure is connected, DO NOT use as performance may be affected and there could
be a safety hazard.
7.
According to local requirement standards and strong recommendation of the manufacturer, a gas shut-off
valve may be needed between the gas supply pipeline and gas-pressure regulator. Whether the installation
of a gas shut-off valve has any local requirements should be judged by the gas installation professional.
8.
Coat some dedicated pipe sealant for gas pipeline in all the pipe joints. The sealant should be rated for use
with and resistant to the action of gas.
9.
After connecting the appliance to the gas system, check for leaks at joints and pipe fittings; to do so, use
soapy water or a specific leak detector (spray). DO NOT use open flame.
10. When first started, it may take a little longer to light due to the air existing in the new pipeline. If it doesn’t
light up, turn the ignition switch off for 3min to allow any gas to exhaust before trying again to prevent
from deflagration.
11.
This appliance should be installed on a stable, level and non-combustible surface (e.g. cement, ceramic tile,
terrazzo or metal surface). Verify all local regulations. Make sure to leave clearance for proper ventilation.
12.
The device can be used only when four legs are installed correctly and the item is stable and level. DO NOT
move during operation.
13.
This device should only be used in a non-combustible area. DO NOT install on a flammable floor or around
other combustible objects.