1-13 

It allows you to deactivate the ultrasonic sensor port by using remote start function. After 

cancel remote start the input is activated again. 

1-14 

This function is available with CAN Bus module. In case you are using read only mode > 

Magicar will only read data from CAN (trunk, door, hood). In read/write mode > data will read and 
write to CAN (trunk, door, hood, lock and unlock, indicators, lock and unlock except closing 
windows.). In mode 3 it iwill read/write and close windows > in this mode Magicar can close 
windows when arming. This function is depending on car type. 

 

Programming menu No.2 

ƒ

  When the doors are opened and ignition is on, keep the buttons 

and

 IV

 pressed for 2 sec. 

Options 

No. 

Function 

Button I 

Button II 

Button III 

Button IV 

2-01 

Trunk output time 

0.5 sec 

2 sec 

3 sec 

4 sec 

2-02 

Door lock impulse 

0.8 sec 

4 sec 

2 x 0.8 sec 

15 sec 

2-03 

Door unlock impulse 

0.8 sec 

4 sec 

2 x 0.8 sec 

2-04 

Door lock/unlock 

impulse during remote 

start 

Off 

Lock impulse 

after remote start 

Unlock impulse  

before remote start 
&lock impulse after 

remote start 

2-05 

Door lock impulse after 

remotely started engine 

will go Off 

Off  

On 

2-06 

Parking lights 

Normal mode 

Continuous mode 

Pulse mode 

2-07 

Start output (TACH) 

ST-1 ST-2 

ST-3 

2-08 

AUX 1 

0.5 sec 

5 sec 

40 sec 

Latch 

2-09 

AUX 2 

0.5 sec 

5 sec 

40 sec 

Latch 

2-10 

AUX 2 BYPASS 

function 

On Off 

2-11 

Shock sensor on/off 

during AUX output 

On Off 

2-12 

Cold start 

Off 

0 ºC 

-5 ºC 

-10 ºC 

2-13 

Arm/disarm by OEM 

remote control 

Enabled Disabled 

 

 

 

Function explanation: 

 

2-01

   Impulse time set-up for trunk output. 

2-02

   Impulse time set-up for door lock.  

2-03

   Impulse time set-up for door unlock. 

2-04  

You can set the central door lock outputs reactions when remote starting activated. Advisable 

if you need the door open at remote starting.  

2-05

 

Option to lock the vehicle after remote starting. 

2-06

   Using this function, you can set the lights control by the alarm mode.  

 - normal – mainly for direct control of hazard lights by (-) or (+). 
 - 1-2 mode – designed to control hazard lights by the button (see page 13). 

2-07

 

Duration of engine starting sequence. 

2-08

 

Duration of negative impulse for AUX output No.1 (grounded when activated) 

2-09

 

Duration of negative impulse for AUX output No.2 (grounded when activated) 

2-10

  It is possible to set the AUX output No 2 as a bypass output. In this case the output will be 

activated when remotely started, and can be used e.g. for the transponder bypass module. When 
remote starting is finished, the output will be deactivated.  

2-11

  It allows you to deactivate a shock sensor by using additional outputs in case connected 

device is causing sensor reaction. 

2-12

  It allows you to set the temperature at which, if the regular starting function on, remote 

starting will be carried out. But in case the temperature is higher than the pre-set one, starting will 
not be carried out! 

 

2-13

  When function is enabled then is possible to arm and disarm system by Magicar 

and factory remote controls. Function is only available when system is connected with 
CAN Bus module.

 

Summary of Contents for M870AS

Page 1: ...MAGICAR M870AS EN Car alarm with two way remote and remote start system Installation guide...

Page 2: ...English EN...

Page 3: ...al functions 10 Programming menu No 1 11 Programming menu No 2 12 VIII CALIBRATION OF THE FUNCTION HAZARD LIGHT MODE 13 IX VALET MODE 14 Entering valet mode without a pin code 14 Entering valet mode w...

Page 4: ...II PLACING When fitting each component consider properly the right place for a microwave interior sensor if fitted Since this sensor is working on magnetic principle it is very sensitive to a magnetic...

Page 5: ...carried out in a safe place in an appropriate distance from busy roads and on a flat surface Before the installation get all necessary equipment ready e g servos diodes relays etc When receiving a car...

Page 6: ...blocking wire 3 green Ignition Output connect to the switchboard to the 12V wire when ignition on Supplies power to the starter wiring 4 black Chassis Grounding grounding It must be firmly fixed to t...

Page 7: ...tween 7 14V immediately after the engine is started engine rpm scanning connect to the point where impulses are in proportion to the revs when engine is running e g crankshaft scanner gear box scanner...

Page 8: ...y use a 30A fuse when connecting to the relay 1 yellow AUX1 output rating capacity 250mA 2 yellow white AUX2 output rating capacity 250mA or the Transponder by pass control The output is grounded when...

Page 9: ...eans the sensor is mains operated 2 white input of additional sensor reacting on 3 red power supply of 12 V V CONNECTING OF CLUTCH SENSOR This connecting is needed in case the car when starting requir...

Page 10: ...beep once to confirm the access of the Programming mode 3 Within 2 seconds of the step 1 press button IV as many times as is the order number of the function you want to set After each pressing of bu...

Page 11: ...rvation mode set up For reservation mode setting to carried out transmission must be in a neutral position emergency brake pulled up with the engine running By turning ignition off the engine remains...

Page 12: ...t Off 0 C 5 C 10 C 2 13 Arm disarm by OEM remote control Enabled Disabled Function explanation 2 01 Impulse time set up for trunk output 2 02 Impulse time set up for door lock 2 03 Impulse time set up...

Page 13: ...arm needs you can use the hazard light button mode In this case the alarm using the lights output replaces a hazard light switch Fig 1 In the programming menu 2 06 you can set the continuous mode Mode...

Page 14: ...most vehicles this position is located two clicks forward from the Off position 2 Turn the ignition off The lights on the dashboard should be turned off 3 Steps 1 and 2 must be repeated for a total of...

Page 15: ...ons for primary setup of security code Function in Programming menu 1 04 must be set Disarmed ignition on Doors opened engine off Programming of security code 1111 9999 1 Ignition is on 2 Open the doo...

Page 16: ...ree times and lights will flash three times XI WIRING DIAGRAM FOR DOOR LOCKING SYSTEM Fig 1 Original built in central power lock with a switch inside the doors A motor at the control level are require...

Page 17: ...2 yellow 1 white 1 purple fuse 15A 2 purple 3 white 4 grey 5 grey white CN 2 Light NO Light NO 12V output to siren Trunk COM Trunk N O Common wire Trunk wire Trunk solenoid Unlock NC Unlock NO Unlock...

Page 18: ...parts as well as onto the box Warning Any alternations or additions to the system will automatically invalidate the installation certificate INSTALLATION CERTIFICATE I the undersigned as a profession...

Reviews: