20
T06
Stabilization duration time in Ignition
230
sec
T07
Interval of Periodic Cleaning repetition
30
min
T08
Periodic Cleaning duration time
20
sec
T09
Delay time for the Safety - Er01
10
sec
T10
Delay time for the Safety - Er02
20
sec
T11
Delay time to exit Standby
30
sec
T13
Minimum duration time of the Extinguishing Phase
300
sec
T14
Pre-Extinguishing for lack of flame Waiting time
120
sec
T15
Waiting time for Extinguishing in Safety
60
sec
T16
Final Cleaning duration time
60
sec
T17
Delay time combustion power change
15
sec
T18
Delay time combustion power change exiting Ignition
30
sec
T22
Delay time to enter Standby
10
sec
T29
Pre-loading waiting time in Ignition
90
sec
T40
Delay time for the Auger activation if there is a Pellet
Safety Valve
0
sec
T41
Working time of the Pump if T42 expired
20
sec
T42
Maximum idle time of Pump P1 and Pump P2 or of the
Valve
60
ore
T43
Timer to switch from Modulation to Standby if boiler
temperature
> (Boiler TheD23) and A13=1, 2
30
sec
T46
Working time of the Valve if T42 expired
10
sec
T57
Minimum duration time of Standby phase
30
sec
T58
Brazier Final Cleaning in Standby
120
sec
T66
System operating hours before it goes into Service Block
1600
ore
T67
System operating hours before the message ‘Cleaning’ is
shown
0
ore
T68
Delay time to restore the original value of the Boiler
Thermostat in
case of ceased DHW demand
30
sec
T69
Delay on the activation at the maximum speed of the
Heating Fan if exhaust flue gas temperature > thermostat
Th07
60
sec
T88
Maximum time of power supply lack for the system to go
back into its previous state.
60
sec
T89
Maximum time of power supply lack for the system to go
back into Recovery Ignition.
5
min
Settings Menu
Parametro
Descrizione Funzione
Hevo
14
Hevo 18
Hevo 21
U.M
A01
0
Room thermostat = Ignition/Extinguishing
1
n°
1
Room thermostat = Run Mode/Modulation;
2
Room thermostat = Run Mode/Standby-
Extinguishing
3
Room thermostat Block the Pump1
4
Room thermostat = Run Mode/Standby andblock
Pump1 until Th21
5
Room thermostat = RunMode/Modulation in Wood
and Run mode/Standby-Extinguishing in
Pellet;
6
Not Used
7
Not Used
A08
0
Not Used
0
n°