4
Technical data
TECHNICAL DATA
HEVO 14
HEVO 18
HEVO 21
Nominal
Reduced
Nominal
Reduced
Nominal
Reduced
Thermical Power kW
14
4,3
18,5
4,32
21,3
4,3
Nominal Technical power kW
13,2
4
17,1
4
19,5
4
performance - %
93
92,5
91,5
92,5
91,7
92,5
Consumption per hour – Kg/h *
2,8
0,8
3,75
0,85
4,32
0,8
Average smokes temperature - °C
154
83
158
83
160
83
Average draft – Pa
10
10
10
Inner tank capacity - Kg
20
20
20
Autonomy – h *
7
25
5 ½
25
5
25
Heatable volume (nominal) – mᵌ **
350
410
490
Air taking - Ø
50
50
50
Smokes exit - Ø
80
80
80
Max operational pressure - bar
2.5
2.5
2.5
Tension – Frequency
230V / 50 Hz
230V / 50 Hz
230V / 50 Hz
Weight – Kg
85
85
85
*
Consumption and autonomy vary depending on the qualoty of the pellet
**
Condifering an energy need of kcal per mᶾ. Values have been calculated following the norm EN14785:2006