SETUP

– Please read all instructions before proceeding –

OPERATION

Initial Assembly

To facilitate in the shipment of your pressure
washer, some items require minor assembly.
Refer to the 

Initial Assembly

sheet included for

instructions.

Lubrication

Prior to initial operation ensure that the oil level of
the pump is to the halfway mark of the oil gauge
window. Do not overfill. Use only Magikist high
pressure pump oil or equivalent non-foaming, non-
detergent, 40 weight #1 compressor oil. Do 

not

use automotive, transmission, or hydraulic oils, or
brake fluid.

Motor Voltage

Ensure that your power supply matches that of the
pressure washer. Do not use any other circuit
unless the motor is rewired by a licensed
electrician. If the pressure washer is unwired, a

licensed electrician should be retained in order to
carry out the proper installation.

Water Inlet Connection

The water inlet connection is a 3/4” female hose
coupling located on the front right side of the
water tank. It is connected to a float assembly
which automatically maintains the correct water
level in the water reservoir.

Attach your water supply hose to the water inlet
connection and turn the water on. Leave the water
supply turned on. Ensure that your water supply is
of adequate capacity such that the water reservoir
does not run empty.

Do not disconnect the suction line between the
pump and the water reservoir and feed the pump
directly without the use of a pressure reducing
valve to reduce inlet pressure to 20 PSI.

Startup Procedure

Ensure that the oil level of the pump is to the
halfway mark of the oil gauge window as
described under 

Setup

.

Attach the water supply hose to the water inlet
connection and turn the water on. Leave the water
supply turned on.

WARNING: 

IF CONNECTION IS MADE TO A

POTABLE WATER SYSTEM, THE SYSTEM
SHALL BE PROTECTED AGAINST BACKFLOW.

ADVERTISSEMENT:

SI CET APPAREIL EST

RACCORDÉ À UN RÉSEAU D’EAU POTABLE,
CE DERNIER DOIT ÊTRE PROTÉGÉ CONTRE
LES RETOURS.

Ensure that the power switch for the electric motor
is in the OFF position. Connect the electric motor
to the power supply.

Grasp the trigger gun firmly and turn the power
switch for the electric motor to the ON position.

Pull back on the trigger of the spray gun to spray.
If after a short while only a trickle of water is
coming out the the spray nozzle or if the water is
spurting out, you may need to purge air from the
pump. See the subsection 

Purging Air

for

instructions on purging air from the pump.

WARNING: 

DO NOT SPRAY ELECTRICAL

APPARATUS AND WIRING.

ADVERTISSEMENT: 

IL EST DANGEREUX DE

TROP ARROSER LE MATÉRIEL ET LES
CÂBLES ÉLECTRIQUES.

SPEX S

ERIES

HIGH PRESSURE WASHERS

OPERATING MANUAL

Reviews: