Installation
MKGD Series Gas Griddle
L25-054 Rev. 1 (01/12)
7
1/2" BOLTS (4)
BRACKET (2)
MOUNT FLUSH
TO FRONT
(SUPPLIED)
(SUPPLIED)
NUTS & BOLTS
INCLUDED
WITH STAND
REAR
Figure 4
NOTICE
Larger models have 6 threaded receiving holes, but require only the four 1/2" bolts on each corner to
mount the griddle.
1. Remove (4) existing 1/4-20 nuts and bolts
from the rear corners of the equipment
stand.
2. Align the 2 bolt holes on the rear corners of
the stand with the 2 bolt holes on the rear
mounting brackets. Orient the brackets as
shown in Figure #4 on this page.
3. Install the provided rear mounting brackets
(2) to the rear corners by using the existing
1/4-20 hardware that were removed in step
1, tighten securely.
4. Carefully place the griddle on the
equipment stand.
5. Once the griddle is on the stand, position
the griddle on the stand so that the front
edge of the base is flush with the front of
the equipment stand. If the griddle is the
only appliance to be mounted on the stand,
then both sides of the griddle should be
flush with the sides of the equipment stand.
6. When positioned properly, the threaded
receiving holes in the griddle base should
be aligned with mating clearance holes at
the front of the equipment stand, and with
the clearance holes in the rear mounting
brackets. Install the provided 1/2" bolts and
tighten securely.
1.6.4. Leveling Instructions
NOTICE
Equipment stands are shipped from the
factory with the legs or casters set to the
minimum height adjustment. Units should be
leveled at time of installation, failure to do so
could cause the griddle to operate
improperly.
1. Identify the corner of the stand that needs to
be adjusted, remove the weight load from
the corner to be leveled.
2.
Legs-
using a wrench, or pliers turn the leg
bullet, See Figure 5, CCW to raise the
height of the equipment stand. There is ½”
to ¾” of adjustment.
Casters-
Using a Flat Head screwdriver,
loosen the set screws of the caster to be
leveled, See Figure 5.Turn the collar of the
caster CCW to raise the height of the
equipment stand. There is ¾” of adjustment.
After leveling adjustment is complete, re-tighten set screws.
3. Check the levelness of the equipment, if necessary Repeat steps 1 and 2.
NOTICE
This appliance may only be installed with casters provided by the manufacturer. When installed with
casters, a gas connection complying with ANSI Z21.69/CGA-6.16 and a quick disconnect device
complying with ANSI Z21.41/CAN 1-6.9. It must also be installed with a restraining device to guard
against putting any strain on the gas connections when the unit is moved.
Figure 5