1. PH SENSOR
2. Winterizing pH & ORP sensors (if installed)
3. PROCEDURE TO FOLLOW
XIV. TREATMENTS (IMAGI SERENITY)
iMAGI Serenity is an automated processing system that must be installed and adjusted by your distributor.
The only settings that can be adjusted by you on the advice of your distributor are the pH and Chlorine treatment
instructions, accessible via the
treatment icon
on page 2.
•
The pH set point adjustment
on the left must be adjusted with the
+ or - keys.
• The setting
of the chlorine set point in ppm
on the right must be adjusted with the
+ or - keys.
Commissioning of treatments
To turn on the treatments (pH and Chlorine) you must press the adjustment button
for each treatment and
press
OFF
to activate the treatment.
If the key is
ON
in green the treatment is active.
Each canister is equipped with a level rod that
must be set approximately 10 cm above the
bottom of the canister to warn the user of
the low level of reactive product. (See table on
page 25)
Information: Lack of water treatment
If you see this information it is because there is a lack of water
flow in the analysis chamber.
Possible causes are:
• Switching off the filter pump
• Incorrect adjustment of the float in the analysis chamber
• The wrong by-pass setting
• Clogged cartridge
• Suction strainer clogged