EN
37
8 Technical Data
Arctic DF36-C
403
269
360
30
723
392
232
286
368
118
289
134
168
1 L
723
30
392
376
232
134
168
208
289
458
360
269
403
2
1,5/2
L
0,
5
L
Arctic DF50-C
403
269
360
30
723
392
232
286
368
118
289
134
168
1 L
Arctic DF36-C/DF50-C/DF60-C
Arctic DF60-C
723
30
392
134
289
289
168
466
232
54
8
1,5/2
L
1 L
* 4 °C cooling temperature
Model Arctic
DF36-C
DF50-C
DF60-C
Capacity
36 L
50 L
60 L
Consumption
80 W
Temperature Range
−20 °C up to +20 °C
Voltage DC
12/24 V
Mains Voltage AC
100/230 V
Dimensions L x W x H (mm)
723 x 360 x 368 723 x 360 x 458
723 x 360 x 548
Weight
14 kg
15.5 kg
17 kg
Consumption 24h at 16 °C*
220 Wh
167 Wh
237 Wh
Consumption 24h at 32 °C*
322 Wh
386 Wh
326 Wh
Cooling Zones
2
Battery Protection
✔
LED Display
✔
Electronic Control
✔
Pull Function
✔
USB Connection
✔
Flexible Lid
X