The corresponding mode will be saved as soon as the letter
stops blinking.
PV = Protection Value
Undervoltage protection, as soon as this voltage is reached,
the device immediately switches off all consumers and can-
not be switched on again.
SV = Startup Value
If this voltage is dropped below, the compressor will not start
to cool down again. The control remains active until the volta-
ge rises again and the device can operate normally or the vol-
tage drops below the Protection Value (protective shutdown).
Mode
Low
Medium
High
12 V
PV
8.5
10.1
11.1
SV
10.9
11.4
12.4
24 V
PV
21.3
22.3
24.3
SV
22.7
23.7
25.7