Area
Description
Method of Inspection
Normal Condition
Findings Pass or
Fail
Timing
Notes
Operator Interface
Guide blocks
•
Visual inspection
•
Cycle deck up and down several times
Blocks are not damaged or worn and move freely in the vertical slide
Quarterly
Operator Interface
Gas spring mounting • Mounting studs • Rod and body connectors • Preload screws are tight
Manual / V
isual
inspection
Components are tight and connectors engaged fully with studs
Quarterly
Electrical
Wiring • Wire connections • Wire crimps, connectors and solder joints
Manual inspection
No loose connections, crimps or solder joints
Quarterly
Electrical
Control boards
Manual / V
isual
inspection
•
No loose components
•
Wiring harness connectors are securely in place
•
Wiring harnesses are not damaged
Quarterly
Electrical
Operation
Cycle deck up and down several times
•
Deck should move through entire range of motion without tripping circuit breaker
•
Buttons should not stick in down position
Quarterly
Operator Interface
Gas spring condition and operation
•
Visual inspection
•
Disconnect cylinders from studs per instructions in manual and try to compress the spring
•
Rods should be straight and free of oil
•
Spring should not compress easily and return to fully extended position if compressed
Annually