10
INSTALLATION
CLAMP INSTALLATION
This unit features a mounting yoke with integrated clamp attachment points, as well as a safety
cable loop located near the fluid tank (see the illustration below). When mounting this fixture to
truss, be sure to secure appropriately rated clamps (not included) to the mounting yoke, and attach
a separate
SAFETY CABLE of the appropriate rating to the safety cable loop.
RIGGING
Overhead rigging requires extensive experience, including but not limited to: calculating working
load limits, understanding the installation material being used, and periodic safety inspection of all
installation material and the device. If you lack these qualifications, do not attempt the installation
yourself. Improper installation can result in bodily injury.
SAFETY CABLE
ALWAYS ATTACH A SAFETY
CABLE WHEN INSTALLING
THIS UNIT IN A SUSPENDED
ENVIRONMENT TO ENSURE
THAT THE UNIT WILL NOT
FALL IN THE EVENT THAT
THE CLAMP FAILS.
SAFETY CABLE
LOOP
MOUNTING CLAMP
ATTACHMENT POINT