14
R E M O T E D E V I C E M A N A G E M E N T ( R D M )
NOTE: In order for RDM to work properly, RDM enabled equipment must be used throughout the
entire system, including DMX data splitters and wireless systems.
Remote Device Management (RDM) is a protocol that sits on top of the DMX512 data standard for
lighting, allowing the DMX systems of the fixtures to be modified and monitored remotely. This proto-
col is ideal for instances in which a unit is installed in a location that is not easily accessible.
With RDM, the DMX512 system becomes bi-directional, allowing a compatible RDM enabled con-
troller to send out a signal to devices on the wire, as well as allowing the fixture to respond (known as a
GET command). The controller can then use its SET command to modify settings that would typically
have to be changed or viewed directly via the unit’s display screen, including the DMX Address, DMX
Channel Mode, and Temperature Sensors.
FIXTURE RDM INFORMATION:
RDM Code
Device Model ID
Personality ID
22A6H
1110
1-ch (1)
2-ch (2)
4-ch (3)
Please be aware that not all RDM devices support all RDM features, and therefore it is important to
check beforehand to ensure that the equipment that you are considering includes all of the fea-tures
that you require.
The following parameters are accessible in RDM on this device:
[0x1000] Identify Device
[0x00F0] DMX Start Address
[0x00C0] Software Version Label
[0x0060] Device Info
[0x0080] Device Model Description
[0x0081] Manufacturer Label
[0x0082] Device Label
[0x0050] Supported Parameters
[0x00E1] DMX Personality Description
[0x00E0] DMX Personality
[0x0200] Sensor Definition
[0x0201] Sensor Value
Summary of Contents for MAGMA FOG 1500IP-II
Page 1: ...User Manual MAGMA FOG 1500IP II...
Page 28: ......