BLUEPIRAT RAPID | USER MANUAL/
page 37 of 67
13
Service and safety instructions
Note according to standard EN55011:2009
The device is used in an industrial environment. Due to occurring, grid-bound as well as radi-
ated disturbances, it might possibly be difficult to ensure compliance with electromagnetic com-
patibility in other environments.
Cleaning
The device may only be cleaned with a clean cloth slightly dampened with water. Other cleaning
agents such as gasoline, alcohol, etc., may not be used.
Maintenance
The device is maintenance-free. The case must not be opened by the customer. Unauthorized
modifications will void the warranty.
Fuse
In case of failure, the customer may change the fuse of the cable set or fuses accessible from
outside only. The fuse may be replaced with a fuse of the same type only and nominal current
rating.
Disposal
Disposal of the unit must be in accordance with the statutory laws and regulations.
Instruction on installation
Assembly of the device shall only take place in all three specified axes.
Operational temperature
Operation of the device shall only be performed within the temperature range specified in the
data sheet.
All tests to determine the valid operational temperature are performed under laboratory condi-
tions. In real operation deviating temperatures can occur. Internal cut-off mechanisms exist, that
prevent impermissible heating of the device’s components.
A sufficient ventilation is to be taken into consideration. The unit and other components shall not
be stacked atop each other provided that there is no adequate cooling ensured and the device
shall be used in ambient temperatures exc25°C.
During operation under unfavorable circumstances case temperatures that 70°C
can occur, as the metal case contributes directly for the passive cooling of the unit. At
elevated ambient temperatures the case shall not be touched due to risk of injury. Opera-
tion of the device is only permissible in industrial premises with restricted access.
Storage conditions
The device may only be stored within a temperature range of - 40 °C to + 85 °C.
Condensation
During condensation the unit must not be activated. For this purpose appropriate waiting peri-
ods must be taken into consideration.
Environmental conditions
The unit must not be used in outdoor areas or unfavorable environmental conditions such as
moisture, high air humidity or dust. Furthermore it is forbidden to operate the device in flamma-
ble or explosive atmospheres. The maximum power supply voltage must not 30V.
Overvoltage can destroy the device and voids the warranty.