BLUEPIRAT SERIES | CAMERA USER GUIDE/
page 80 of 93
Note:
Quad channel means that up to 4 video streams are recorded in one window.
Attention:
With the setting Quad-View, the same maximum frame rate must be set for all cameras!
You can find this setting in the camera configuration under Axis Setup => Basic Setup =>
Video Stream => Camera 1, Camera 2,... At different frame rates, otherwise connection
breaks may occur.
If you select
option 2
or
3
, please type the IP address of the AXIS P7214 / F44 in the approach-
ing fields below.
Figure 14.6: Setting an IP address
14.2.1.3
Configuring the cameras
In the folder
[Camera]
click
[Camera #1]
(1)
and activate the checkbox for
Camera interface
active
(2)
. Choose the connector
(3)
depending on the Ethernet port the Video Encoder / net-
work camera is connected to. Enter the Video Encoders / network cameras IP address
(4)
. If the
AXIS P7214 is used, the IP address is already specified in the general settings. It is taken from
there.
If you have chosen to use the recommended user and password, you can activate the checkbox
for
Default password
(5)
.
If you have chosen to use your own password, deactivate the checkbox for
Default password
(5)
and type in your chosen
“admin” password from before
(6)
.
Type in the additional IP-alias of the data logger
(7)
. The data logger has to be in the same sub-
net as the Video Encoder / network camera.