blue PiraT Mini
User Guide
Datum: 21.09.2016
Seite 43 von 56
blue_PiraT_Mini_UserManual_V2.4.1.doc
14 Data sheet
General data
bPMini CAN
bPMini LIN
bPMini MOST
bPMini FlexRay
Nominal power supply
voltage
13.8 V
13.8 V
13.8 V
13.8 V
Power supply voltage
5 to 30 V (at system
start up logger needs >
7 V)
5 to 30 V (at system
start up logger needs >
7 V)
5 to 30 V (at system
start up logger needs >
7 V)
5 to 30 V (at system
start up logger needs >
7 V)
Reverse polarity protec-
tion of the supply volt-
age
Yes
Yes
Yes
Yes
Resistance to short-
circuiting
Yes
Yes
Yes
Yes
Power consumption /
operating (typ.)
300 mA (@ 13.8 V)
300 mA (@ 13.8 V)
300 mA (@ 13.8 V)
300 mA (@ 13.8 V)
Power consumption /
operating (peak.)
< 400 mA (@ 13.8 V)
< 400 mA (@ 13.8 V)
< 400 mA (@ 13.8 V)
< 400 mA (@ 13.8 V)
Power consumption /
standby
< 1 mA
< 1 mA
< 1 mA
< 1 mA
Operating temperature
- 40 °F to + 158 °F
- 40 °F to + 158 °F
- 40 °F to + 158 °F
- 40 °F to + 158 °F
Storage temperature
- 40 °F to + 185 °F
- 40 °F to + 185 °F
- 40 °F to + 185 °F
- 40 °F to + 185 °F
Weight (ca.)
250 g
250 g
250 g
250 g
Power Management
bPMini CAN
bPMini LIN
bPMini MOST
bPMini FlexRay
Startup time
from standby to full
operation
< 15 s
< 15 s
< 15 s
< 15 s
Start of logging -
starting from standby
CAN, LIN, Serial,
Analog, Digital
< 60 ms
CAN, LIN, Serial,
Analog, Digital
< 60 ms
CAN, LIN, Serial,
Analog, Digital, MOST
< 60 ms
CAN, LIN, Serial,
Analog, Digital,
FlexRay
< 60 ms
Start of logging -
full start
+ ca. 500 ms
+ ca. 500 ms
+ ca. 500 ms
+ ca. 500 ms
Start of logging -
Ethernet / OABR, Au-
toNeg off
< 120 ms
< 120 ms
< 120 ms
< 120 ms
Standby Mode
Configurable time
without bus load
Configurable time
without bus load
Configurable time
without bus load
Configurable time
without bus load
Wake
CAN-HS, CAN-LS,
LIN, Serial, KL 15,
[ON / Trigger] button
CAN-HS, CAN-LS,
LIN, Serial, KL 15,
[ON / Trigger] button
CAN-HS, CAN-LS,
LIN, Serial, KL 15,
[ON / Trigger] button,
MOST
CAN-HS, CAN-LS,
LIN, Serial, KL 15,
[ON / Trigger] button,
FlexRay
Data loss by power loss
If the device is
switched off due to
sudden power loss, up
to 60 sec. of data may
be lost.
If the device is
switched off due to
sudden power loss, up
to 60 sec. of data may
be lost.
If the device is
switched off due to
sudden power loss, up
to 60 sec. of data may
be lost.
If the device is
switched off due to
sudden power loss, up
to 60 sec. of data may
be lost.
Case
bPMini CAN
bPMini LIN
bPMini MOST
bPMini FlexRay
Size (ca.)
4,13" x 3,35" x 1,30"
(105 x 85 x 33 mm)
4,13" x 3,35" x 1,30"
(105 x 85 x 33 mm)
4,13" x 3,35" x 1,30"
(105 x 85 x 33 mm)
4,13" x 3,35" x 1,30"
(105 x 85 x 33 mm)
Operating controls
Push-button to start
and shut down data
logger and to set
markers
Push-button to start
and shut down data
logger and to set
markers
Push-button to start
and shut down data
logger and to set
markers
Push-button to start
and shut down data
logger and to set
markers
LEDs (STATE, ACTIVE)
Yes
Yes
Yes
Yes
Connectors
bPMini CAN
bPMini LIN
bPMini MOST
bPMini FlexRay
Front connectors
2x Gbit Ethernet, SD
card, Micro--USB 2.0
2x Gbit Ethernet, SD
card, Micro--USB 2.0
2x Gbit Ethernet, SD
card, Micro--USB 2.0
2x Gbit Ethernet, SD
card, Micro--USB 2.0
Rear connectors
2x Gbit ETH
SUB-D 44-pol:
Power supply, 8x HS-
CAN, 1x LS-CAN, 2x
LIN, 5x Serial, 2x
Analog In, 2x Digital In,
2x Gbit ETH
SUB-D 44-pol:
Power supply, 2x HS-
CAN, 1x LS-CAN, 8x
LIN, 5x Serial, 2x
Analog In, 2x Digital In,
2x Gbit ETH
SUB-D 15-pol:
Power supply, 1x HS-
CAN, 1x HS-/LS-CAN
(mux), 3x Serial, 1x
Serial/ECL (mux), 2x
2x Gbit ETH
SUB-D 44-pol:
Power supply, 4x HS-
CAN, 1x LS-CAN, 2x
LIN, 5x Serial, 2x
Analog In, 2x Digital In,