10 Logging data
10.1 Setting markers
Interesting occurrences can be marked by the
[ON / Trigger]
button at the front panel or at the
Remote Control / Remote Control Voice by setting a timestamp. When you are pressing this
button, the data logger saves the current time to the internal storage as a marker.
It is possible to configure the data logger to send a CAN message as an acknowledgement of
setting a marker
Additionally
complex triggers
are making it possible to define a message that triggers a mark-
er. In all cases, marker triggers are debounced.
When downloading the data, the client displays all markers in a data overview. In this data
overview, the client can be configured to transfer the data close to selected markers.
10.1.1
Setting marker with an extern push button
It is also possible to use the digital inputs and
complex triggers
function to realize an external
marker button. Important is to set the used interface active and in the <General settings> of this
interface the
[Timing Mode]
is enabled and the <Sampling interval> is set to 100 ms or more.
Figure 10.1: General settings
Figure 10.2: Setting Trigger with Digital Input