18
Starter Disable:
(Also Applies if ALA-RPS2 was Installed to Interrupt Other Circuits)
1. Enter the vehicle and close all the entrances.
2. Arm the alarm using the transmitter.
3. Turn the ignition key to the start position. The engine will not crank over.
4. Turn the ignition key to the off position and disarm the alarm.
5. Turn the ignition key back to the start position and the engine will crank over and start.
Last Door Automatic Arming:
(If Programmed On)
Note:
The automatic arming feature will not operate unless the alarm input triggers have been
connected directly to existing or newly installed door jamb pins. Current sensing alone will not
activate the automatic arming circuit.
1. Set the ignition key to the on position, then turn it off.
2. Exit the vehicle and close the door. The horn/siren will chirp 1 time when the door is closed.
3. The LED will begin to flash fast.
4. After 30 seconds have passed , you will hear another chirp. The alarm is now armed.
5. The LED will flash at a regular rate indicating an armed condition.
LED Status Indicator Operation:
LED is off = Alarm is disarmed.
LED is flashing = Alarm is armed.
LED is flashing in a 1 flash hold sequence = Tamper warning, alarm was triggered by the current
sensing sensor.
LED flashing in a 2 flash hold sequence = Tamper warning, alarm was triggered by the hood or trunk.
LED flashing in a 3 flash hold sequence = Tamper warning, alarm was triggered by an opened door.
LED flashing in a 4 flash hold sequence = Tamper warning, alarm was triggered by an electronic sensor.
LED is on steady = Alarm is in the valet mode. (Ignition key is “on”)
LED flashes once every 5 seconds = Alarm is in the valet mode. (Ignition key is “off”)
LED is flashing fast = Automatic arming timer is counting down or RF tamper rearming timer is
counting down.
Horn/Siren Chirp Alarm Status Indication:
Note:
This feature can be programmed off, see “Remote Feature Programming” for details.
One chirp = Alarm is armed and all input trigger wires are clear.
Two chirps = Alarm is disarmed and has not been tampered with.
Four chirps = Tamper indicator, alarm is disarmed.
Power Door Lock/Unlock:
(If Installed)
1. Press the “LOCK” button on the transmitter, the locks will become locked.
2. Press the “UNLOCK” button on the transmitter, the locks will become unlocked.
Ignition Controlled Door Locking:
(Door lock activation must be installed)
When programmed on, the ignition controlled locking feature will lock the door locks 3 seconds
after the ignition key is turned on. When the ignition key is turned off, the door locks will unlock.
(Depending on the mode the ignition locking is programmed to)
Note:
If a protected entrance (door) is open when the ignition key is set to the on position, the door
locks will not lock. This is a non-deletable protective measure.
Step 9: Speciality Feature and Optional Equipment Testing