5
Thermostat
The device features a built-in thermostat that automatically shuts
OFF the device in case of overheating or abnormal operation. If the
device becomes too hot (overheating), the thermostat and fuse will
activate and stop the device from working. Allow it to cool down for
approximately 15 minutes and the fuse will reset automatically. The
device can be used again.
In case the device does not operate normally after it has cooled
down, it is recommended to disconnect the device from the mains
power and to reset the thermostat fuse manually by pressing the
reset button key
10
in the small reset
9
buttonhole until you hear a
click. Please use the reset butt on key
10
for this action.
After resetting the thermostat, connect the device again to the
mains power and follow the steps described at section “Using the
device”.
After resetting the device, the thermostat has been reset, the
boiling point needs to be set to recover normal heating function.
Set the temperature at 100 and volume at 000 (continuous flow),
and allow it to dispense for ± 1 minute.
Drainage stopper
In case the device will not be used for a long period of time, clean it
and remove the remaining water.
Open the drainage stopper on key
11
at the bottom of the base by
turning it counter-clockwise, so the remaining water can flow out of
the device. Once all the remaining water has been removed, place
the drainage stopper on key
11
back by turning it clockwise and
make sure it is properly tightened.
Note!
In case of any water leakage after filling the water tank,
check that the drainage stopper is properly tightened.
Drip tray
The device is equipped with a removable drip tray
5
.
When the drip trap is mounted, the available space between the
drip tray and spout = ± 17 cm.
When the drip tray
5
is full, hold the device at the top, and remove
the drip tray by moving it upwards, releasing it from the drip tray
holders.
Empty the drip tray
5
, rinse it with running water, dry it with a dry
cloth and place it back by sliding it over the drip tray holders
5
with a gentle push.
EN 06
4) CLEANING - MAINTENANCE & DESCALING
4) CLEANING - MAINTENANCE & DESCALING
Descaling
To maintain its performance, it is recommended to descale the device on a monthly basis in case of regular use.
Only use a toxic free detergent such as citric acid or vinegar!
Pour some citric acid or vinegar into the water tank (above the MIN mark), preferably 2 litres, and operate it
with the temperature set at 100 °C and volume set at 000 (continuous flow). Dispense the liquid until the tank is
empty.