TV-KIT-010 Instructions Magnavox HVG Repair - 7621
Last Updated Monday, 29 October 2012 14:51
Slowly pull up on the first High Voltage Wire as shown in the picture. The wires are very tight at
first because of the yellow clips. This is normal. Just increase the amount of upward pull force
on the wires until they pop out. An alternative method is to pop out the yellow plastic clips first.
The problem with this method is sometimes the clips break as they are being removed and the
broken pieces get stuck in the old flyback.
If you place your other hand on the flyback it will provide more leverage.
Once the wire is removed touch it to the metal rack as shown in the photo. This will ground it out
and drain the high voltage from the CRT/wires. You may or may not see a spark. The spark is
the stored voltages in the CRT tubes being discharged to ground. This will not damage
anything.
Once done you can safely handle the wires.
Repeat the above steps for the remaining RED wires that are still connected to the High Volage
Generator.
You may want to touch the wires to the metal frame each time before you work on the set. This
will help insure that the voltages are drained and the wires are safe to handle.
Once you have safely discharged the HGV voltage from the CRT wires you can now remove the
rest of the cables from the circuit board.
Remove all the cables on the flyback board! Make sure you label them with a marker so that
you know where to put them back!
9 / 17