LY71 Change of display resolution (polarity)
1/3
With the display , press
key once
The display will be . (Selection of input axis)
Press key to select a condition.
When you have made your selection, press key to save your settings.
To finish the basic settings, follow steps
②
and
③
below.
Ver.1 (2021.1) CS&S
LY71
Initial
setup
Item
No option
BCD unit
(LZ71-B)
BCD unit (LZ71-B)
Comparator unit (LZ71-KR)
Comparator unit
(LZ71-KR)
1-axis input
2-axes
input
2-axes
input
1-axis
input
2-axes
input
2-axes
input
1-axis input
1-axis input
2-axes input
Basic
settings
Addition /
subtraction
function
Not used Not used
use
Not
used
Not used
use
Not used
Not used
use
Advanced
Settings
Display
resolution
A axis
A axis
B axis
A axis
A axis
A axis
B axis
A axis
A axis
A axis
A axis
Combination with optional unit and settings items
Power ON
Basic settings
⇒
Input axis
⇒
Change
Input axis selection
(addition / subtraction function)
Input 1
Input 1 +Input 2
Input 1 – Input 2
-Input 1 +input 2
-(Input 1 + Input 2)
Input 1, input 2 (independent)
NOTE: When using comperate unit, 2-axis
independent display is not possible.
LY71 Change of display resolution (polarity)
* If you do not know the output resolution of the measurement unit, refer to the separate "Initial setup manual".
Purpose of change
Operation
Explanation
Change the polarity for the input axis
using the 2-axes addition / subtraction
function in the input axis selection
Change the input axis choices in the basic
settings
Change the measurement unit resolution
Change the length measurement unit resolution in
the basic settings. And check the display
resolution in the detailed settings.
Change the display resolution
Change the display resolution in the detailed
settings
Change the display polarity
(Counting direction is reversed)
Change the display resolution in the detailed
settings
Advanced Settings
⇒
Display resolution
⇒
Change
The operation method for changing the display resolution differs depending on the purpose and conditions of the change.
Select the purpose and conditions to be changed from the table below and perform the operation.
Basic settings
⇒
Measurement unit resolution
⇒
Change
Basic settings
⇒
Input axis
⇒
Change
Advanced Settings
⇒
Display resolution
⇒
Change polarity
Set to basic settings mode.
Turn key “ON” while the AC adapter is energized.
Press and hold key for 3 seconds after the lamp changes from blinking to off.
①
About 2 sec
Press
key once to automatically switch to advanced settings mode.
The display will be
.
Press
key, the display becomes the normal display.
③
④
Switch from basic settings to normal count mode.
Press
key once and the display will change to
.
Press
key once and the display will change to
.
②