8
(E)
SQ47-Z Series, CH22 Series
Installation example
Example 1 (recommended): Installation when a stop surface of the scale and the sensor head is
made with the bracket.
Scale installation accuracy is improved when a stop surface is made. Th
is also simplifi es reinstallation of
the scale.
1. Check and adjust the scale bracket’s parallelism with respect to the machine guide, and then secure in
place.
0.05
MG
0.1
MG
0.05
MG
0.1
MG
Scale bracket
Scale bracket
<When using the stop surfaces>
<When using parallel pins>
Stop surface height
Parallel pin
protrusion length
Secure a scale bracket stop surface height
of 2 mm (recommended).
Secure a parallel pin protrusion length
of 2 mm (recommended).
Unit: mm
Fig. 3-3