2. Check and adjust the height and parallelism of the sensor head bracket.
Make sure that the sensor head and the scale of the sensor head bracket do not interfere.
0.05 or less
0.05
MG
0.05
MG
77
±
0.5
77
±
0.5
77
±
0.5
77
±
0.5
0.05 or less
Scale bracket
Scale bracket
Sensor head
bracket
Sensor head
bracket
Sensor head
bracket
Sensor head
bracket
<When using the stop surfaces>
<When using parallel pins>
Unit: mm
Fig. 3-4
3. Bring the scale into contact with the stop surfaces, apply a thread-locking agent to the threaded areas,
and install.
Scale bracket
Scale bracket
Scale
Scale
Thread-locking agent
Thread-locking agent
<When using the stop surfaces>
<When using parallel pins>
Parallel pin
M6 × 12
(9 N
t
m)
M6 × 12
/tN
Fig. 3-5