(E)
3
SQ57-Z Series, CH22 Series
1-5. Functional Safety
Th
is product is a functional safety magnescale which is compliant with EN 61800-5-2:Ed. 2.0: 2016 /
IEC 61508:2010 / IEC 62061:2005 SC3 SIL 2 and EN ISO 13849-1:2015 Cat.3 / PL d.
Behavior of the product when a fault arises.
:
Th
e product shift s to a safe state within 5 ms when a
dangerous fault is detected.
Dangerous fault : An error
(
*
1)
in position measurement exceeds ±1 mm of reference.
Safe state
: Th
e product sends the alarm information to the controller via the DQ100, holds
the alarm information, and shift s to a safe state.
Recovery process : When the magnescale trouble is resolved, normal communication is restored
immediately aft er the product receives the Alarm Reset signal from the
controller. Otherwise, the alarm is held.
(
*
1) : Th
e error position information described here is a threshold value which is considered as a dangerous
fault value in terms of functional safety and is not the accuracy of the product. As for the accuracy
of the product, see Section 6. “Specifications.”
Th
e product is maintenance-free and it is not necessary to replace the parts periodically.
Functional safety specifi cations
Mode of operation
Item
High demand / continuous mode
Probability of
dangerous failure
Operating temperature : +50°C
PFH = 38 × 10
-9
(1/h)
Operating temperature : +25°C
PFH = 10 × 10
-9
(1/h)
Operating temperature : 0°C
PFH = 5.7 × 10
-9
(1/h)
MTTFd
85.4 years (High)
DCavg
79.08% (Low)
Hardware fault tolerance
1
Product type
Type B
SIL
2
SC (Systematic capability)
3
Normative references
Standard Applied
specifi cation
IEC 61508:2010
Functional safety
IEC 62061:2005+A1: 2012+A2: 2015
Functional safety
EN ISO 13849-1:2015
Functional safety
IEC 60664-1:2007
Clearances (between PWB (Printed wiring board) patterns)
specifi cation
EN 61800-5-2:E.d. 2.0: 2016
Requirements related to Table D.16 Motion and position
feedback sensors
IEC 62061:2005+A1: 2012+A2: 2015
Table D.1 Failure Mode
IEC 60068-2-1, IEC 60068-2-2,
IEC 60068-2-6, IEC 60068-2-14,
IEC 60068-2-27, IEC 60068-2-30,
IEC 60068-2-31
Environmental Tests
IEC 61000-6-4:2006 +A1:2010
CISPR 16-1-1:2010, clause 4
CISPR 16-1-4:2010, clause 4.4 and 5
CISPR 16-2-3:2010, clause 7.2
Emission
IEC 61000-6-2:2016
IEC 61326-3-1:2017
IEC 61000-4-2:2008
IEC61000-4-3:2006 +A1:2007 +A2:2010
IEC 61000-4-4:2012
IEC 61000-4-6:2013
IEC 61000-4-8:2009
Immunity
For details about functional safety, contact our functional safety department.
45 Suzukawa, Isehara-shi, Kanagawa 259-1146, Japan TEL: +81 (0)463 92 1011 FAX: +81 (0)463 92 1012
Summary of Contents for SmartSCALE SQ57
Page 3: ...SQ57 Z Series CH22 Series J 1...
Page 4: ...SQ57 Z Series CH22 Series 2 J...
Page 6: ...SQ57 Z Series CH22 Series ii J...
Page 10: ...SQ57 Z Series CH22 Series 4 J 1 6 2006 42 EC...
Page 12: ...SQ57 Z Series CH22 Series 6 J 3 7 3 1 CH22 SQ57 M6 M4 M6 M8 B A 3 2 L 3 1 3 1 7...
Page 20: ...SQ57 Z Series CH22 Series 14 J 3 3 5 mm 1 0 N m 242 2 3 1 1 0 N m 3 14 1 0 N m O SQ57 Z O 3 15...
Page 23: ...SQ57 Z Series CH22 Series J 17 5 SIEMENS DRIVE CLiQ 3 5 DRIVE CLiQ...
Page 28: ...SQ57 Z Series CH22 Series 22 J 8 3 2...
Page 32: ...ii E SQ57 Z Series CH22 Series...
Page 58: ...ii G SQ57 Z Series CH22 Series...
Page 82: ......
Page 83: ...1 SQ57 Z Series CH22 Series...