8
(E)
SQ57-Z Series, CH22 Series
2. Check and adjust the height and parallelism of the sensor head bracket.
Make sure that the sensor head and the scale of the sensor head bracket do not interfere.
0.05 or less
0.05
MG
0.05
MG
77
±
0.5
77
±
0.5
77
±
0.5
77
±
0.5
0.05 or less
Scale bracket
Scale bracket
Sensor head
bracket
Sensor head
bracket
Sensor head
bracket
Sensor head
bracket
<When using the stop surfaces>
<When using parallel pins>
Unit: mm
Fig. 3-4
3. Bring the scale into contact with the stop surfaces, apply a thread-locking agent to the threaded areas,
and install.
Scale bracket
Scale bracket
Scale
Scale
Thread-locking agent
Thread-locking agent
<When using the stop surfaces>
<When using parallel pins>
Parallel pin
M6 × 12
(9 N
t
m)
M6 × 12
/tN
Fig. 3-5
Summary of Contents for SmartSCALE SQ57
Page 3: ...SQ57 Z Series CH22 Series J 1...
Page 4: ...SQ57 Z Series CH22 Series 2 J...
Page 6: ...SQ57 Z Series CH22 Series ii J...
Page 10: ...SQ57 Z Series CH22 Series 4 J 1 6 2006 42 EC...
Page 12: ...SQ57 Z Series CH22 Series 6 J 3 7 3 1 CH22 SQ57 M6 M4 M6 M8 B A 3 2 L 3 1 3 1 7...
Page 20: ...SQ57 Z Series CH22 Series 14 J 3 3 5 mm 1 0 N m 242 2 3 1 1 0 N m 3 14 1 0 N m O SQ57 Z O 3 15...
Page 23: ...SQ57 Z Series CH22 Series J 17 5 SIEMENS DRIVE CLiQ 3 5 DRIVE CLiQ...
Page 28: ...SQ57 Z Series CH22 Series 22 J 8 3 2...
Page 32: ...ii E SQ57 Z Series CH22 Series...
Page 58: ...ii G SQ57 Z Series CH22 Series...
Page 82: ......
Page 83: ...1 SQ57 Z Series CH22 Series...