5.
Prepare and connect the wire ends as shown in Figure 8 and Figure 9. Refer to Wire Gauges,
Tightening Torques, and Crimp Terminals on page 18 to confirm that the proper tightening torque is
applied to each terminal. Take particular precaution to ensure that each wire is properly connected
and wire insulation is not accidentally pinched into electrical terminals.
Figure 8: Preparing Ends of Shielded Cable
Figure 9: Preparing and Connecting Cable Wiring
WA R N I N G
Fire Hazard.
Tighten terminal screws to the specified tightening torque. Loose electrical connections could
result in death or serious injury by fire due to overheating. Tightening screws beyond the
specified tightening torque may cause erroneous operation, damage the terminal block, or
cause a fire.
N O T I C E
Heat shrink tubing or electrical tape may be required to ensure that cable shielding does not
contact other wiring. Insufficient insulation may cause a short circuit and damage the option or
drive.