DRIVE SETUP
88
Drive Faults
The following Faults are custom to the
SA407 Generation 2 DSD 412 software.
Function Error Code Listing
*** DCU ERRORS ***
DISPLAY # - DESCRIPTION
13 = ILLEGAL INSTRUCTION
14 = LINE 1010 EMULATOR
15 = LINE 1111 EMULATOR
16 = PRIVELEGE VIOLATION
17 = DIVIDE BY ZERO
21 = WATCHDOG TIMEOUT
22 = RESERVED INTERRUPT
23 = UNINITIALIZED INTERRUPT
24 = TRACE EXCEPTION
26 = SPURIOUS EXCEPTION
97 = OVERSPEED TRIP
98 = TACH/ENCODER LOSS
99 = REVERSE TACH/ENCODER
100 = NOT A NUMBER
101= MATH OVERFLOW
102 = MATH UNDERFLOW
103 = FLOATING POINT DIVIDE BY ZERO
104 = SIGN ERROR IN SPEED REG
112 = BAD PCDU POINTER
113 = MISSING PCU
114 = LOCKED UP QUEUES
115 = MULTIPLEXER CONFIG. ERROR
117 = 20 SEC COMM. START FAULT
118 = 150 MSEC COMM. MSG FAULT
220 = DCU ROM BUS ERROR
221 = DCU RAM BUS ERROR
222 = DCU NVRAM BUS ERROR
223 = DCU DPRAM BUS ERROR
232 = UNKNOWN BUS ERROR
240 = DCU ROM BUS ERROR
241 = DCU RAM ADDRESS ERROR
242 = DCU NVRAM ADDRESS ERROR
243 = DCU DPRAM ADDRESS ERROR
252 = UNKNOWN ADDRESS ERROR
***DRIVE FAULTS/ERRORS***
DISPLAY # - DESCRIPTION
400 = MOTOR OVERLOAD
401 = EXCESSIVE FIELD CURRENT
402 = CONTACTOR FAULT
403 = 5-MIN FULL FIELD FAULT
404 = OPEN ARMATURE CIRCUIT FAULT
405 = SAFETY CIRCUIT FAULT
406 = 10% LOW LINE ALARM
407 = EXCESSIVE DCU CEMF ALARM
408 = EXCESSIVE PCU CEMF FAULT
409 = UNEXPECTED PCU RESET
410 = SPEED ERROR FAULT
411 = MAX AUTO-RESETS ATTEMPTED
413 = FIELD CURRENT TRACKING FAULT
414 =
SOFTWARE COMPATABILITY FAULT
*** PCU ERRORS ***
DISPLAY # - DESCRIPTION
900 = PCU LOOP FAULT
901 = PCU IST FAULT
902 = POWER SUPPLY FAULT
903 = LINE SYNC FAILURE
904 = LOW LINE FAULT
905 = FIELD LOSS
906 = DCU FAILURE
907 = THERMISTOR FAULT
908 = OVER TEMPERATURE
909 = EXCESSIVE RIPPLE
910 = BLOWN FUSE
911 = SHORTED SCR
912 = OPEN SCR
915 = PARAMETER SETUP FAULT
916 = FORCING FAULT
917 = REVERSE ARM. V. FEEDBACK
919 = RATED VAC. SETTING ERROR
920 = RATED ARM. VOLT. SETTING
921 = BRIDGE RATING FAULT
923 = RATED ARM. I. SETTING ERROR
924 = RATED FIELD I. SETTING ERROR
925 = FIELD PCB SENSE FAULT
926 = PCU WATCHDOG TIMEOUT FAULT
929 = FIELD CURR. WON’T GO TO ZERO
930 = FIELD CURR. WON’T GO TO RATED
931 = OPEN CIRCUIT CEMF FAULT
932 = CLOSED CIRCUIT CEMF FAULT
933 = ARM CURRENT WON’T INCREASE
934 = LOW ARM INDUCTANCE
935 = WRONG BUS VS ARM VOLTS FBK
936 = E-STOP OPENED DURING TEST
937 = LOW ARMATURE VOLTS FBK
938 = LOW BUS VOLTS FBK
939 = FIELD FB HARDWARE FAILURE
940 = FIELD A/D OVERFLOW FAILURE
941 = MOTOR THERMOSTAT OPEN
Prot = CORRUPTED NV RAM DATA
Summary of Contents for DSD 412
Page 1: ...DSD 412 DC Elevator Drive Technical Manual CS00407 rev 06...
Page 6: ...6...
Page 102: ...MAINTENANCE 102 Figure 24 Connector and E prom Locations...
Page 103: ...MAINTENANCE 103 Figure 25 Test Point Locations...
Page 115: ...OUTLINE DRAWING 100A 115 Figure 26 Drive Chassis Outline DSD 412 100 Amp...
Page 116: ...OUTLINE DRAWING 190A 116 Figure 27 Drive Chassis Outline DSD 412 195 Amp...
Page 117: ...OUTLINE DRAWING 300A 117 Figure 28 Drive Chasis Outline DSD 412 300 Amp...
Page 118: ...LAYOUT DRAWING 100A 118 Figure 29 Layout DSD 412 100 Amp A3 A1 A2 A2 L1 NEG GND L2 L3 POS...
Page 119: ...LAYOUT DRAWING 195A 119 Figure 30 Layout DSD 412 195 Amp A3 A1 A2 A2...
Page 120: ...LAYOUT DRAWING 300A 120 Figure 31 Layout DSD 412 300 Amp A3 A1 A2 A2...
Page 121: ......