IMPULSE
®
•G+ Mini Technical Manual
November 2020
Page 108
5.7.2 Power Loss Ride Thru
5.7.3 Stall Prevention
Parameter
Name
Function
Range
Default
L02.01
Power-Loss Selection
Enables/disables the Power Loss Ride
Thru function
00–02
00
00 Disable
Disabled
01 Enable
VFD will restart if power returns within L02.02
02 CPU Power Active
VFD will restart if power returns before CPU
shutdown
L02.02
Power-Loss Ride Thru
Time
Time in which power has to return before a UV
fault occurs
0.0–25.5 sec
Varies
L02.03
Power-Loss BaseBlock
Time
Output turn on delay after power resumes
0.1–5.0 sec
Varies
L02.04
Power-Loss V/F Ramp
Time
Voltage recovery time after speed search
is complete
0.0–5.0 sec
Varies
L02.05
PUV Detection Level
Under voltage fault detection level
150–210 VDC
300–420 VDC
190/380
L02.07
Power-Loss Ride Thru
Accel
Acceleration time after a Power Loss Ride Thru
0.0–25.5
0.0
Parameter
Name
Function
Range
Default
L03.01
Stall Prevention Accel
Select
Stall prevention during acceleration.
00–02
01
00 Disable
01 General Purpose
02 Intelligent
CAUTION
This function automatically adjusts the output frequency, acceleration and/or deceleration rates in order to
continue operation without tripping or “stalling” the motor.
Summary of Contents for IMPULSE G+ Mini
Page 15: ...IMPULSE G Mini Technical Manual November 2020 Page 15 Figure 2 1 Long Time Storage...
Page 18: ...IMPULSE G Mini Technical Manual November 2020 Page 18 Figure 2 4 Diagram C...
Page 181: ......
Page 182: ...IMPULSE G Mini Adjustable Frequency Crane Controls Technical Manual November 2020...