6.2.2 Braking Circuit
Test Equipment - Analog Ohmmeter set to R x 1 scale or digital multimeter set to the diode check.
Figure 6-1: Braking Circuit
Step No.
Ohmmeter Positive
Lead
Ohmmeter Negative
Lead
Expected Reading
(Analog Meter)
Expected Reading
(Digital Meter)
1
Connect to B2
Connect to B1
10 Ohms
0.5 Volts
2
Connect to B1
Connect to B2
Infinite Ohms
OL displayed
3
Connect to B2
–
Infinite Ohms
OL displayed
4
–
Connect to B2
Infinite Ohms
OL displayed