418: Frequency Reference Source
Selection
419: Frequency Reference Modbus
420: Output Frequency Reference
(decimal)
421: Run Command Selection Results
422: Modbus Communication
Reference
601: Motor Secondary Current (lq)
602: Motor Excitation current (ld) - OLV
ONLY
605: Output Voltage Reference (Vq) -
OLV ONLY
606: Output Voltage Reference (Vd) -
OLV ONLY
607: ACR (q) Output - OLV ONLY
608: ACR (d) Output - OLV ONLY
620: Frequency Reference Bias (Up/
Down2)
621: Offset Frequency
O01.02
Power-On Monitor
03
01–05
-
01: Frequency Reference (U01.01)
02: Forward/Reverse
03: Output Frequency (U01.02)
04: Output current (U01.03)
05: User Monitor (O01.01)
O01.03
Display Sealing
00
00–03
-
00: 0.01 Hz
01: 0.01%
02: r/min
03: User-set
O01.10
User-set Display Maximum Units
06000
00000–60000
-
O01.11
User-set Display Decimal
02
00–03
-
00: No Decimal Point
01: 0.1
02: 0.01
03: 0.001
O02.01
Local/Remote Key
00
00, 01
-
00: Disable
01: Enable
Parameter
Parameter Name
Default
Range
Units