Table 5-18: Fault Trace
Monitor
Name
Function
Units
U02.01
Current Fault
Most recent fault detected before being reset
-
U02.02
Last Fault
Most recent fault after being reset (same as U03.01)
-
U02.03
Frequency Reference @ Fault
Freq ref when fault was detected
Hz
U02.04
Output Frequency @ Fault
Output freq when fault was detected
Hz
U02.05
Output Current @ Fault
Output current when fault was detected
A
U02.06
Motor Speed @ Fault (OLV Only)
Motor speed when fault was detected
Hz
U02.07
Output Voltage @ Fault
Output voltage when fault was detected
VAC
U02.08
DC Bus Voltage @ Fault
DC Bus voltage when fault was detected
VDC
U02.09
Output Power @ Fault
Output power when fault was detected
HP/kW
U02.11
Input Terminal Status @ Fault
Input terminal status when fault was detected
-
U02.12
Output Terminal Status @ Fault
Output terminal status when fault was detected
-
U02.13
Operation Status @ Fault
VFD status before fault was detected
-
U02.14
Elapsed Time @ Fault
Elapsed time when fault was detected
hr
U02.15
Speed Reference During Soft Start
@ Fault
Speed reference during soft start at previous fault
%
U02.16
Motor q-Axis Current
During Fault
Displays the q-axis current for the motor at the previous fault
(U02.02).
%
U02.17
Motor d-Axis Current
During Fault
Displays the d-axis current for the motor at the previous fault
(U02.02).
%