IMPULSE
®
•G+ Mini Technical Manual
November 2020
Page 16
2.3 Dimensions and Heat Loss - Open Chassis
** Heat loss for carrier frequency of 2.0 kHz (heavy duty).
Voltage
Model
Diagram
W
H
D
W1
H1
d
Wt
lb (kg)
Total Heat
Loss (W)**
Dimensions in Inches (mm)
230V
2001-G+M
A
2.68
(68)
5.04
(128)
2.99
(76)
2.20
(56)
4.65
(118)
M4
1.3 (0.6)
14.7
2003-G+M
A
2.68
(68)
5.04
(128)
4.25
(108)
2.20
(56)
4.65
(118)
M4
2.0 (0.9)
24.0
2005-G+M
A
2.68
(68)
5.04
(128)
5.04
(128)
2.20
(56)
4.65
(118)
M4
2.4 (1.1)
36.7
2008-G+M
B
4.25
(108)
5.04
(128)
5.08
(129)
3.78
(96)
4.65
(118)
M4
3.7 (1.7)
61.9
2011-G+M
B
4.25
(108)
5.04
(128)
5.41
(137.5)
3.78
(96)
4.65
(118)
M4
3.7 (1.7)
81.3
2017-G+M
B
5.51
(140)
5.04
(128)
5.63
(143)
5.04
(128)
4.65
(118)
M4
5.3 (2.4)
122.7
2025-G+M
C
5.51
(140)
9.70
(246)
5.51
(140)
4.80
(122)
9.76
(248)
M5
8.4 (3.8)
248.5
2033-G+M
C
5.51
(140)
9.70
(246)
5.51
(140)
4.80
(122)
9.76
(248)
M5
8.4 (3.8)
282.6
2047-G+M
C
7.09
(180)
11.42
(290)
6.42
(163)
6.30
(160)
11.18
(284)
M5
12.1 (5.5)
389.7
2060-G+M
C
8.66
(220)
13.78
(350)
7.36
(187)
7.56
(192)
13.23
(336)
M6
20.3 (9.2)
563.8
460V
4001-G+M
B
4.25
(108)
5.04
(128)
3.19
(81)
3.78
(96)
4.65
(118)
M4
2.2 (1.0)
19.1
4002-G+M
B
4.25
(108)
5.04
(128)
3.90
(99)
3.78
(96)
4.65
(118)
M4
2.6 (1.2)
27.1
4003-G+M
B
4.25
(108)
5.04
(128)
5.41
(137.5)
3.78
(96)
4.65
(118)
M4
3.7 (1.7)
38.3
4004-G+M
B
4.25
(108)
5.04
(128)
6.06
(154)
3.78
(96)
4.65
(118)
M4
3.7 (1.7)
57.4
4005-G+M
B
4.25
(108)
5.04
(128)
6.06
(154)
3.78
(96)
4.65
(118)
M4
3.7 (1.7)
67.1
4007-G+M
B
4.25
(108)
5.04
(128)
6.06
(154)
3.78
(96)
4.65
(118)
M4
3.7 (1.7)
75.7
4009-G+M
B
5.51
(140)
5.04
(128)
5.63
(143)
5.04
(128)
4.65
(118)
M4
5.3 (2.4)
97.1
4014-G+M
C
5.51
(140)
9.70
(246)
5.51
(140)
4.80
(122)
9.76
(248)
M5
8.4 (3.8)
173.4
4018-G+M
C
5.51
(140)
9.70
(246)
5.51
(140)
4.80
(122)
9.76
(248)
M5
8.4 (3.8)
219.4
4024-G+M
C
7.09
(180)
11.42
(290)
5.63
(143)
6.30
(160)
11.18
(284)
M5
11.5 (5.2)
283.8
4031-G+M
C
7.09
(180)
11.42
(290)
6.42
(163)
6.30
(160)
11.18
(284)
M5
12.1 (5.5)
344.3
NOTE:
Applications such as high duty cycles in conjunction with high ambient temperatures or other unique environmental
conditions can impact VFD ratings. Please consult factory.
Summary of Contents for IMPULSE G+ Mini
Page 15: ...IMPULSE G Mini Technical Manual November 2020 Page 15 Figure 2 1 Long Time Storage...
Page 18: ...IMPULSE G Mini Technical Manual November 2020 Page 18 Figure 2 4 Diagram C...
Page 181: ......
Page 182: ...IMPULSE G Mini Adjustable Frequency Crane Controls Technical Manual November 2020...