IMPULSE
®
•G+ Mini Technical Manual
November 2020
Page 43
4.2.6.4
Speed Reference (A01.04)
This parameter will automatically define the input terminals for the selections listed below.
(X-Press Programming) for details.
Setting
Description
00
2-Speed Multi-step — Defines Terminal S3 = 2nd speed.
01
3-Speed Multi-step — Defines Terminals S3 and S4 as speeds 2 and 3 respectively.
02
5-Speed Multi-step — Defines Terminals S3-6 as speeds 2-5.
03
2-Step infinitely variable — Terminals S1 and S2 = B01.01 (Reference 1) and speed hold. Terminal
S3 = Accelerate.
04
3-Step infinitely variable — Terminals S1 and S2 = B01.01 (Reference 1). Terminal S3 = Speed Hold.
Terminal S4 =Accelerate.
05
Uni-polar analog — Terminals S1 and S2 = A directional input. Terminal A1 = 0-10V. For 4-20mA
control, configure terminal A2.
Summary of Contents for IMPULSE G+ Mini
Page 15: ...IMPULSE G Mini Technical Manual November 2020 Page 15 Figure 2 1 Long Time Storage...
Page 18: ...IMPULSE G Mini Technical Manual November 2020 Page 18 Figure 2 4 Diagram C...
Page 181: ......
Page 182: ...IMPULSE G Mini Adjustable Frequency Crane Controls Technical Manual November 2020...