Table 5-112: Fault Trace Monitors
* Available only for 4810 and 41090 models.
Monitor
Display
Function
Units
U02-01
Current Fault
Most current fault detected before being reset
-
U02-02
Last Fault
Most recent fault after being reset
-
U02-03
Frequency Ref
Freq ref when the fault was detected
Hz
U02-04
Output Freq
Output freq when the fault was detected
Hz
U02-05
Output Current
Output current when the fault was detected
A
U02-06
Motor Speed
Motor Speed when the fault was detected
Hz
U02-07
Output Voltage
Output voltage when the fault was detected
VAC
U02-08
DC Bus Voltage
DC Bus voltage when the fault was detected
VDC
U02-09
Output Power
Output power when the fault was detected
HP/kW
U02-10
Torque Reference
Torque reference when the fault was detected
%
U02-11
Input Term Sts
Input terminal status when the fault was detected
-
U02-12
Output Term Sts
Output terminal status when the fault was detected
-
U02-13
Inverter Status
VFD status when the fault was detected
-
U02-14
Elapsed Time
Elapsed time when the fault was detected
Hrs
U02-15
SFS Output
Speed reference for the soft starter when the fault was detected
Hz
U02-16
Motor Iq Current
Q-axis current for the motor when the fault was detected
%
U02-17
Motor Id Current
D-axis current for the motor when the fault was detected
%
U02-20
Actual Fin Temp
Temperature of the heatsink when the fault was detected
°C
U02-27*
Motor Temp (NTC)
Temperature of the motor when the fault was detected
°C
U02-28*
Fault Axis
Module where the fault occurred at a decimal number
-