Function
Description
Loop active pulse B
When a vehicle drives into loop B (rising flank), the output with this function
emits a pulse.
Loop inactive pulse A
When a vehicle drives out of loop A (falling flank), the output with this
function emits a pulse.
Loop inactive pulse B
When a vehicle drives out of loop B (falling flank), the output with this
function emits a pulse.
Direction 1 Pls A => B
The vehicle drives from direction A to B. When the vehicle leaves loop A in
the direction of loop B, this output emits a counter pulse of 300 ms.
A
B
DO
NO/NC
t = 300 ms
Mag001
13
Direction 1 Pls B => A
The vehicle drives from direction B to A. When the vehicle leaves loop B in
the direction of loop A, this output emits a counter pulse of 300 ms.
A
B
DO
NO/NC
t = 300 ms
Mag0001
14
Direction 2 Pls A => B
The vehicle drives from direction A to B. When the vehicle drives on loop A
in the direction of loop B, this output emits a counter pulse of 300 ms.
A
B
DO
NO/NC
t = 300 ms
Mag001
15
Summary of Contents for MHTM MicroDrive
Page 1: ...Operating Instructions Barrier MHTMTM MicroDrive Doc ID 5815 5001US Version 02 6...
Page 4: ...Barrier MHTM TM MicroDrive 4 5815 5001US Version 02 66...
Page 10: ...Barrier MHTM TM MicroDrive 10 5815 5001US Version 02 66...
Page 178: ...Barrier MHTM TM MicroDrive 178 5815 5001US Version 02 66...
Page 179: ......
Page 180: ...Barrier MHTM TM MicroDrive 180 5815 5001US Version 02 66...
Page 182: ...Barrier MHTM TM MicroDrive Appendix 182 5815 5001US Version 02 66...
Page 184: ......
Page 186: ......
Page 188: ......
Page 195: ...Barrier MHTM TM MicroDrive 5815 5001US Version 02 6 195...