Mode 2: Deadman
Typical application
This mode is suitable for barriers on parking places, factory
premises, etc. The barrier must be operated by a person.
Function
The barrier is operated by two buttons.
For opening the barrier, the button "open" must be pressed until
the barrier is open all the way. For closing the barrier the button
"close" must be pressed until the barrier is closed.
If no button is pressed, the barrier stops. If the "close" button is
then pressed, the barrier opens completely first for safety reasons
and then closes.
If the closing process is interrupted, only opening will be possible.
A signal at the "Close" input would in this case open the barrier. If
the "Close" signal is removed, the opening process is interrupted. If
there is a pulse at the "Open high priority" input, the barrier opens
completely.
Supported input functions
Input function
Signal type
Supported/
Not supported
Open low priority
(priority 3)
Permanent signal Supported
Open low priority with
vend count
– Not
supported
Open high priority
(priority 1)
Pulse or
permanent signal
Supported
Opening loop
–
Not supported
Close
(priority 2)
Permanent signal Supported
Table 36: Supported input functions "Deadman"
See page 97, chapter 9.4.6 "Digital inputs".
Summary of Contents for MHTM MicroDrive
Page 1: ...Operating Instructions Barrier MHTMTM MicroDrive Doc ID 5815 5001US Version 02 6...
Page 4: ...Barrier MHTM TM MicroDrive 4 5815 5001US Version 02 66...
Page 10: ...Barrier MHTM TM MicroDrive 10 5815 5001US Version 02 66...
Page 178: ...Barrier MHTM TM MicroDrive 178 5815 5001US Version 02 66...
Page 179: ......
Page 180: ...Barrier MHTM TM MicroDrive 180 5815 5001US Version 02 66...
Page 182: ...Barrier MHTM TM MicroDrive Appendix 182 5815 5001US Version 02 66...
Page 184: ......
Page 186: ......
Page 188: ......
Page 195: ...Barrier MHTM TM MicroDrive 5815 5001US Version 02 6 195...