Barrier MHTM
TM
MicroDrive
Parameterising control unit
120
5815,5001US / Version 02.66
Function
From direction 1 "Safety loop
Opening loop", the barrier is
opened by an opening signal at one of the digital opening inputs.
Hold-open time is not active in this mode.
The barrier closes in the following cases:
If the vehicle drives over both loops in direction 1 "Safety loop
Opening loop", the barrier closes as soon as the vehicle
leaves the safety loop. The opening loop here does not act as
an extended safety loop.
If a vehicle drives onto the safety loop but leaves it again
backwards, the barrier closes.
If the vehicle does not drive onto any of the two loops, the
barrier remains open until a vehicle drives through or a closing
signal is given.
For barriers with a safety light barrier but no safety loop
installed, see page 136, chapter 10.10.10.
Modes 5 to 8:
Automatic (5) to (8) –
Supported input functions
Input function
Signal type
Supported/
Not supported
Open low priority
Pulse or
permanent signal
Supported
Open low priority with
vend count
Pulse signal
Supported
Open high priority
Pulse or
permanent signal
Supported
Opening loop
–
Supported
Close
Pulse or
permanent signal
Supported
Table 40: Supported input functions "Automatic (5) to (8)"
See page 97, chapter 9.4.6 "Digital inputs".
Summary of Contents for MHTM MicroDrive
Page 1: ...Operating Instructions Barrier MHTMTM MicroDrive Doc ID 5815 5001US Version 02 6...
Page 4: ...Barrier MHTM TM MicroDrive 4 5815 5001US Version 02 66...
Page 10: ...Barrier MHTM TM MicroDrive 10 5815 5001US Version 02 66...
Page 178: ...Barrier MHTM TM MicroDrive 178 5815 5001US Version 02 66...
Page 179: ......
Page 180: ...Barrier MHTM TM MicroDrive 180 5815 5001US Version 02 66...
Page 182: ...Barrier MHTM TM MicroDrive Appendix 182 5815 5001US Version 02 66...
Page 184: ......
Page 186: ......
Page 188: ......
Page 195: ...Barrier MHTM TM MicroDrive 5815 5001US Version 02 6 195...