Barrier MHTM
TM
MicroDrive
Assembly and installation
68
5815,5001US / Version 02.66
8.7
Assemble light barrier post
The light barrier post is attached with 4 foundation anchors each.
Requirements mounting material
MAGNETIC Automation Corporation recommends using
3/8"
anchor bolts.
Refer to the anchor bolt manufacturers installation
requirements.
Assemble light barrier post
1. The foundation must have cured.
2. Drill holes for the foundation anchors according to the
foundation plan, page 60, Fig. 17. In compliance with the
indicated sizes.
Drill-hole distance: 3.94 in (100 mm), square alignment
Depth: 3.15 in (80 mm)
(At this drilling depth, a minimum tensile strength of
2.02 kpf (9 kN) must be guaranteed.)
3. Set four foundation anchors.
4. Set up post upright on foundation.
5. Attach the post to the foundation with the anchor bolts and
tighten the nuts securely.
Summary of Contents for MHTM MicroDrive
Page 1: ...Operating Instructions Barrier MHTMTM MicroDrive Doc ID 5815 5001US Version 02 6...
Page 4: ...Barrier MHTM TM MicroDrive 4 5815 5001US Version 02 66...
Page 10: ...Barrier MHTM TM MicroDrive 10 5815 5001US Version 02 66...
Page 178: ...Barrier MHTM TM MicroDrive 178 5815 5001US Version 02 66...
Page 179: ......
Page 180: ...Barrier MHTM TM MicroDrive 180 5815 5001US Version 02 66...
Page 182: ...Barrier MHTM TM MicroDrive Appendix 182 5815 5001US Version 02 66...
Page 184: ......
Page 186: ......
Page 188: ......
Page 195: ...Barrier MHTM TM MicroDrive 5815 5001US Version 02 6 195...