Pedestrian Barrier High Door MPH 112
Assembly and installation
5817,5005EN / Version 01
39
Dismantle end housing
To mount the pedestrian barrier onto the foundation the end
housing has to be dismantled. See Fig. 11.
1. Open
top
cover.
2. Disconnect the plug for the light barriers (ST1
ST4).
3. Disconnect the plug from Barrier End Display.
4. Undo the connecting screws "end housing
central housing"
in both upper corners.
5. Undo the lower central screw.
6. Remove
end
housing.
7.6
Assembly on the foundation
Risk of crushing
CAUTION!
CAUTION!
Risk of crushing!
In certain circumstances a finger can be crushed
when opening a glass wing.
Therefore:
– If the basic or the end module is directly placed
at a wall, pay attention that there is a minimum
distance of 25 mm between the glass wing edge
and the wall while the glass wing is open.
1. The foundation has been set to the adequate hardness.
2. Drill holes for the anchor bolts according to the foundation
plan.
Observe the minimum distance between the housings.
Refer to Page 22, Fig. 2.
Ensure that the pedestrian barrier is in line.
3. Position barrier modules on the foundation.
4. The pedestrian barrier is fixed by six express anchors to the
ground frame onto the foundation. The mounting material is
included in delivery.