Pedestrian Barrier High Door MPH 112
Configuration of pedestrian barrier
60
5817,5005EN / Version 01
10.2 Configuring the pedestrian barrier
Some functions and parameters of the pedestrian barrier can be
adjusted via two blocks each equipped with 8 DIP switches. For a
detailed description refer to Page 65, Chapter 10.2.1 and Page 63,
Chapter 10.2.2.
The following adjustments or inspections have to be performed:
1. Switch off power supply.
2. Adjust the program mode 2 (MPH) via the DIP switches S2.1
and S2.2.
3. Set passage direction via DIP switches S2.3 and S2.4.
4. Set the "behaviour" when an obstruction is detected via DIP
switch S2.8.
5. Check DIP switch for CAN bus termination and addressing on
all three control units. Refer to Page 86, Chapter 13.3.
NOTE!
Changes to DIP switch settings only become
effective after the power supply to the pedestrian
barrier has been switched off and then on again.
Fig. 25: DIP switch block S1 und S2
1
DIP-switch block S1
2
DIP-switch block S2