Pedestrian Barrier High Door MPH 112
Configuration of pedestrian barrier
5817,5005EN / Version 01
61
10.2.1 DIP switch block S1
DIP S1.x
Function
Description
1
Opening pulse storage
When pulse storage is switched off, the barrier can be
opened by a pulse at one of the two opening inputs. If further
opening pulses are received while the barrier is still open,
they are ignored.
With opening pulse storage activated, several opening pulses
can be stored. The barrier then remains open until the
number of stored pulses is again zero. With each passage,
the number of stored pulses is reduced by one.
Options
OFF: No pulse stored
ON: Up to 5 opening pulses can be stored
2 Buzzer
When it is activated, the buzzer gives a warning in certain
situations.
Continuous tone:
during a reference run (homing) or when
there is a global error
Tone at rapid intervals:
on "tailgating" by a second person
Tone at slow intervals:
for unauthorised access or the
unauthorised presence of a person in the light barrier zone
Options
OFF: Buzzer switched off
ON: Buzzer switched on
The safety delay time is the maximum time for which the lane
remains open after all safety light barriers have been cleared.
On expiry of the safety delay time, the barrier closes. The
safety delay time has four possible settings.
Options
DIP S1.3
DIP S1.4
Safety delay time
OFF OFF 0
s
ON OFF 1
s
OFF ON 2
s
ON ON 3
s
3 and 4
Safety delay time