Pedestrian Barrier High Door MPH 112
Configuration of pedestrian barrier
62
5817,5005EN / Version 01
DIP S1.x
Function
Description
The hold-open time is the maximum time for which the lane
remains open after an opening signal if there is no one in the
lane. On expiry of the hold-open time, the barrier closes if no
one has passed through. The hold-open time has four
possible settings.
Options
DIP S1.5
DIP S1.6
Hold-open time
OFF OFF 2
s
ON OFF 4
s
OFF ON 6
s
5 and 6
Hold-open time
ON ON 12
s
7
Query software version
status
If this function is activated during operation, the version status
of the software is displayed cyclically on the 7-segment
display.
Options
OFF: Normal operating display
ON: Version status of software is displayed
8 Reserved Not
used
Table 10: DIP switch block S1