Pedestrian Barrier High Door MPH 112
Malfunctions
5817,5005EN / Version 01
83
13.2.3 Error codes of the MBC-110
Error code
Description
Corrective action
To be carried
out by
E02
1)
Emergency input IN1 is
interrupted
The signal at IN1+ or IN1- has
been interrupted, e.g. by an
external fire alarm system.
Check if the wires to IN1+ or IN1-
are broken or if the input was
actually interrupted by an external
safety system.
Electrical
specialist
E03
1)
Safety light barrier interrupted
during reference run
The reference run cannot be
carried out because at least one
safety light barrier is covered.
Remove obstruction.
Electrical
specialist
E04
1)
Attempted break-in
Someone has attempted to force
one or both glass wings out of its
closed end position.
Electrical
specialist
E05
1)
Obstruction detection
An obstruction has been detected.
Electrical
specialist
E06
1)
Unauthorised access
The passage was entered in the
wrong direction.
Someone has attempted to pass
through the barrier in the wrong
direction, or a person has stayed
too long in the entry zone without
generating an opening signal.
Electrical
specialist
E07
1)
MBC-110 reset by Watchdog
The MBC-110 has detected a
program sequence error and has
been restarted by Watchdog.
Electrical
specialist
E09
1)
Following by a second person
(tailgating) detected
An unauthorised person has been
detected attempting to follow an
authorised person.
This error can also occur when, for
example, a large piece of luggage
is detected as a following person.
Electrical
specialist
E20
2)
Check sum error in program
memory
Device must be newly programmed
or sent to MAGNETIC for repair.
Electrical
specialist
E21
2)
MMC-120 detected with wrong
software
At least one MMC-120 has been
found to have the wrong application
software.
Download application software
from MBC-110 to MMC-120.
Electrical
specialist