Pedestrian Barrier High Door MPH 112
Malfunctions
84
5817,5005EN / Version 01
Error code
Description
Corrective action
To be carried
out by
E22
2)
MMC-120 detected with wrong
software
At least one MMC-120 has been
found to have the wrong application
software.
Download application software
from MBC-110 to MMC-120.
Electrical
specialist
E30
2)
Error downloading from
MBC-110 to MMC-120
Software in the MMC-120 could not
be deleted.
If necessary repeat download for
several times.
Electrical
specialist
E31
2)
Error downloading from
MBC-110 to MMC-120
No communication with MMC-120
boot loader.
If necessary repeat download for
several times.
Electrical
specialist
E32
2)
Error downloading from
MBC-110 to MMC-120
Re-programming of MMC-120 does
not work.
If necessary repeat download for
several times.
Electrical
specialist
E33
2)
Error downloading from
MBC-110 to MMC-120
Error when activating new MMC-
120 software.
If necessary repeat download for
several times.
Electrical
specialist
E40
2
Minimum angle not achieved on
reference run
During a reference run (homing),
the glass wing mechanism must
move through a minimum angle,
otherwise the reference run cannot
be completed.
Remove obstruction.
Electrical
specialist
E41
2)
Invalid program mode set
DIP switches S2.1 and S2.2 are set
to an invalid program mode.
Select program mode MPH.
Refer to Page 63, Table 11.
Electrical
specialist
E42
2)
MMC-120 cannot be activated
when starting
At least one MMC-120 cannot be
activated by the CAN bus during a
program start.
CAN communication between
MBC-110 and MMC-120 is
malfunctioning, error at MMC-120
Electrical
specialist
E43
2)
Error in MMC-120 detected
during operation
At least one MMC-120 has
detected an internal error.
Read error code via LEDs of MMC-
120. Correct cause.
Refer to Page 88, Table 18
Electrical
specialist
E60
2)
Error when initialising CAN
protocol stack
Internal software error in MBC-110
Electrical
specialist
E61
2)
Error when initialising CAN bus
CAN bus is blocked, e.g. by a short
circuit in the CAN cable.
Correct short-circuit at CAN-cable.
Electrical
specialist