Pedestrian Barrier High Door MPH 112
Electrical connection
5817,5005EN / Version 01
57
8.4.2
MOSFet outputs
Not isolated
Switched voltage 5 – 24V
Switched current 500 mA
MOSFet
output
Function
Description
MOSFet
output 1
Barrier End Display red
cross on entry side
This output controls the red cross in the Barrier End
Display on the entry side.
MOSFet
output 2
Barrier End Display green
arrow on entry side
This output controls the green arrow in the Barrier End
Display on the entry side.
MOSFet
output 3
Barrier End Display red
cross on exit side
This output controls the red cross in the Barrier End
Display on the exit side.
MOSFet
output 4
Barrier End Display green
arrow on exit side
This output controls the green arrow in the Barrier End
Display on the exit side.
Table 9: MOSFet outputs
8.5
Installing access-control devices
Observe the provided assembly dimensions.
3
1
2
3
Wide
4
5
6
400
200
80
(160)
210
210
66
129
238
148
Mag55775079d
Standard
Fig. 24: Maximum installation volume for card reader
Connect access control devices as e.g. card readers to both inputs
IN2 and IN3 according to Page 51, Fig. 20.