Pedestrian Barrier High Door MPH 112
Start-up and operation
72
5817,5005EN / Version 01
Personal protective equipment
The following must be worn during start-up:
Work clothes
Protective gloves
Safety shoes.
11.2 Start-up
Inspection prior to initial start-up
The following inspections must be performed prior to initial start-up:
Check wiring emergency input IN1.
Refer to Page 51, Fig. 21 and Page 55, Fig. 23.
Check connection of digital inputs IN2 and IN3.
Refer to Page 51, Fig. 21.
Check connection of relays outputs 1 to 6.
Refer to Page 51, Fig. 21.
The program mode 2 (MPH) must be set by the DIP switches
S2.1 and S2.2. Refer to Page 63, Table 11.
NOTE!
Remember that the safety light barriers are
activated during a system start. The glass wings
can only close when the safety light barriers are
clear.
Make sure that, when the power supply is switched on, there are
no obstructions to operation of the barrier. The access lane must
be clear.
Every time the power is switched on, the glass wings go to the
closed position. The first closure takes place at reduced speed and
serves as a reference run for the system to learn the end positions.
There are three exceptions:
An opening impulse is present.
The input "Emergency" to controller MBC-110 is interrupted
The safety light barriers are not clear.
11.3 Operation
11.3.1 Switching on and off the pedestrian barrier
Switching on
Switch on pedestrian barrier at the mains switch. The mains switch
is on the mounting plate "Master". Refer also to Page 38, Fig. 11.
Switching off
Switch off pedestrian barrier at the mains switch. The mains switch
is on the mounting plate "Master". Refer also to Page 38, Fig. 11