Malfunctions
5817,5005EN / Version 01
85
Error code
Description
Corrective action
To be carried
out by
No communication with
MMC-120, MMC-120 in operation
CAN cable broken.
Check CAN cable. DE /EN
Plug not correctly inserted.
Insert plug correctly.
Wrong CAN address set
Set correct CAN-address.
Termination resistors not correctly
set.
Set termination resistors correctly.
E62
2)
There is an old firmware on one or
both of the MMC-120
Download software from MBC-110
to MMC-120.
Electrical
specialist
E64
2)
MMC-120 does not answer,
MMC-120 in operation
See Error E62 for possible causes
Electrical
specialist
E65
2)
EEPROM error in MBC-110
The EEPROM memory in MBC-110
could not be read or written in.
Possibly hardware error in
MBC-110
Electrical
specialist
E66
2)
Checksum error in parameter
memory
Hardware defect, send the unit to
MAGNETIC for repair.
Electrical
specialist
E70
1)
Error in light barrier LS 1
Light barrier covered for longer
than 30 seconds. Light barrier dirty
or defective.
Check light barrier.
Electrical
specialist
E71
1)
Error in light barrier LS 2
Light barrier covered for longer
than 30 seconds. Light barrier dirty
or defective.
Check light barrier.
Electrical
specialist
E72
1)
Error in light barrier LS 3A / 3 B
Light barrier covered for longer
than 30 seconds. Light barrier dirty
or defective.
Check light barrier.
Electrical
specialist
E73
1)
Error in light barrier LS 4A / 4B
Light barrier covered for longer
than 30 seconds. Light barrier dirty
or defective.
Check light barrier.
Electrical
specialist
E74
1)
Error in light barrier LS 5
Light barrier covered for longer
than 30 seconds. Light barrier dirty
or defective.
Check light barrier.
Electrical
specialist
E75
1)
Error in light barrier LS 6
Light barrier covered for longer
than 30 seconds. Light barrier dirty
or defective.
Check light barrier.
Electrical
specialist
Table 15: Error codes of the MBC-110
1) Self-resetting error: The pedestrian barrier is still operating. The error code is displayed as long as the error is
pending. If the error is corrected, the error code is displayed again for a max of another 10 seconds.
2) Non-self-resetting error: The pedestrian barrier is out of operation. The error code is shown as long as the error is
pending.