Pedestrian Pivot Barrier
MPP-112 / MPP-122 / MPP-132 / MPP-212 / MPP-222
Configuration of pedestrian barrier
56
5817,0016EN / Version 00
DIP S2.x
Function
Description
8
Multiply brake time
Multiply brake time with the factor 5.
The regular brake time is 10 x 50 ms (0.5 s).
The setting of the DIP-switch S2.8 does not influence the
"Extended brake time" that is set using the DIP switches
S2.5 and S2.6.
For this function to become effective, the pedestrian pivot
barrier has to be switched on and off again.
Options
OFF: The regular brake time is set to 10 x 50 ms (0.5 s).
ON: The extended brake time is set to 50 x 50 ms
(2.5 s).
Table 8: DIP switch block S2
Example for DIP-switches S1.4 and
S2.4 to S2.8
DIP-switches S1.4 and S2.4 to S2.8 are set as follows:
DIP S1.4: ON
DIP S2.4: ON
DIP S2.5: ON
DIP S2.6: ON
DIP S2.7: ON
Since DIP-switch S2.7 takes priority over DIP-switch S2.4, the
"Extended brake time" is effective at every vandalism attempt.
The "Extended brake time" of 30 seconds is set via DIP switches
S2.5 and S2.6.
DIP-switch S1.4 activates "High safety level" and therefore
progressive braking time.
At the first vandalism attempt, the brake remains tightened for 30
seconds. If the blocking element is pushed for more than 30
seconds, the blocking element latches in the second grating and
the DIP switch S1.4 setting "High safety level" becomes effective.