Full Height Turnstile MPT-152
Electrical connection
40
6 Electrical
connection
6.1 Safety
General
WARNING
Danger by inappropriate installation!
Inappropriate installation can causes serious inju-
ries or death.
– Only qualified personnel, authorized by the op-
erator and instructed appropriately, may carry
out installation tasks.
– Pay attention to tidiness and cleanness at the
assembly site! Loose components and tools that
are left lying around cause accidents.
– Install all fastening elements correctly.
Electric voltage
DANGER
Mortal danger by electric voltage!
Touching live parts can be lethal.
Damage to the insulation or to individual compo-
nents can be lethal.
– Switch off the power supply immediately in case
of damage to the insulation and arrange repair.
– Only electrical specialists may carry out work on
the electrical system.
– Switch off voltage supply and secure against re-
activation before performing any work. Test for
absence of voltage.
– Never bypass or deactivate fuses.
– When replacing fuses observe the correct am-
perage specification.
– Keep moisture and dust away from live parts.
Moisture or dust may cause a short circuit.
Electric voltage –
missing safety installations
DANGER
Mortal danger by electric voltage!
The safety installations that are required according
to regional and local regulations must be provided
by the customer. Usually these are:
– Residual current device (RCD)
– Circuit-breaker
– Lockable 2-pole main switch according to
EN 60947-3.